February 23 2014 Could a FUKUSHIMA Style Nuclear Disaster Occur In The UNITED STATES of America ? ANSWER: Yes with an extended Power Grid Outage of 8 days or more..

A Festering Problem

Long before Fukushima, American regulators knew that a power failure lasting for days involving the power grid connected to a nuclear plant, regardless of the cause, would most likely lead to a dangerous radioactive leak in at least several nuclear power plants. A complete loss of electrical power poses a major problem for nuclear power plants because the reactor core must be kept cool as well as the back-up cooling systems, all of which require massive amounts of power to work. Heretofore, all the NERC drills which test the readiness of a nuclear power plant are predicated on the notion that a blackout will only last 24 hours or less. Amazingly, this is the sum total of a NERC litmus test.   Although we have the technology needed to harden and protect our grid from an EMP event, whether natural or man-made, we have failed to do so. The cost for protecting the entire grid is placed at about the cost for one B-1 Stealth Bomber. Yet, as a nation, we have done nothing. This is inexplicable and inexcusable.   Our collectiveinaction against protecting the grid prompted Congressman Franks to write a scathing letter to the top officials of NERC. However, the good Congressman failed to mention the most important aspect of this problem. The problem is entirely fixable and NERC and the US government are leaving the American people and its infrastructure totally unprotected from a total meltdown of nuclear power plants as a result of a prolonged power failure.

Critical Analyses

According to Judy Haar, a recognized expert in nuclear plant failure analyses, when a nuclear power plant loses access to off-grid electricity, the event is referred to as a “station blackout”. Haar states that all 104 US nuclear power plants are built to withstand electrical outages without experiencing any core damage, through the activation of an automatic start up of emergency generatorspowered by diesel. Further, when emergency power kicks in, an automatic shutdown of the nuclear power plant commences. The dangerous control rods are dropped into the core, while water is pumped by the diesel power generators into the reactor to reduce the heat and thus, prevent a meltdown. Here is the catch in this process, the spent fuel rods are encased in both a primary andsecondary containment structure which is designed to withstand a core meltdown. However, should the pumps stop because either the generators fail or diesel fuel is not available, the fuel rods are subsequently uncovered and a Fukushima type of core meltdown commences immediately. At this point, I took Judy Haar’s comments to a source of mine at the Palo Verde Nuclear power plant. My source informed me that as per NERC policy, nuclear power plants are required to have enough diesel fuel to run for a period of seven days. Some plants have thirty days of diesel. This is the good news, but it is all downhill from here.

The Unresolved Power Blackout Problem

A long-term loss of outside electrical power will most certainly interrupt the circulation of cooling water to the pools. My Palo Verde nuclear power plant source informed me that there is no long term solution to a power blackout and that all bets are off if the blackout is due to an EMP attack. A more detailed analysis reveals that the spent fuel pools carry depleted fuel for the reactor. Normally, this spent fuel has had time to considerably decay and therefore, reducing radioactivity and heat. However, the newer discharged fuel still produces heat and needs cooling. Housed in high density storage racks, contained in buildings that vent directly into the atmosphere, radiation containment is not accounted for with regard to the spent fuel racks. In other words, there is no capture mechanism. In this scenario, accompanied by a lengthy electrical outage, and with the emergency power waning due to either generator failure or a lack of diesel needed to power the generators, the plant could lose the ability to provide cooling. The water will subsequently heat up, boil away and uncover the spent fuel rods which required being covered in at least 25 feet of water to remain benign from any deleterious effects. Ultimately, this would lead to fires as well and the release of radioactivity into the atmosphere. This would be the beginning of another Fukushima event right here on American soil. Both my source and Haar shared exactly the same scenario about how a meltdown would occur. Subsequently, I spoke with Roger Landry who worked for Raytheon in various Department of Defense projects for 28 years, many of them in this arena and Roger also confirmed this information and that the above information is well known in the industry. When I examine Congressman Franks letter to NERC and I read between the lines, it is clear that Franks knows of this risk as well, he just stops short of specifically mentioning it in his letter.

Read full Article:

No comments:

Post a Comment

Thanks, Your Comment will appear within the next 24 hours...

Your comment is very much appreciated and helpful to our readership.

.... Morpheus